The LC2030 workstation was designed for training in open and closed-loop control technology. It offers a wide selection of practice options, from simple open-loop control tasks to complex controlled systems.
All signals (0/2…10V DC or 24V DC) are available via 4 mm laboratory sockets on the system control panel. The filling level is recorded via a float switch or a pressure sensor. The filling level is changed by controlling the three pumps and/or the valves. Switches and buttons on the control panel can be used flexibly for operation. Signal lights enable errors and process states to be displayed.
Technical Data
• Dimensions (W x D x H): 520 x 450 x 720 mm
• Container contents: 2 x ca. 8 l
• Weight: approx. 26 kg
Control Loops
• Level control with controllable pump,
• Level control with controllable valve (optional),
• Flow control with controllable pump (optional),
• Flow control with controllable valve (optional),
• Pressure control with controllable pump (optional),
• Temperature control with heating element and cooler (optional).
Open-Loop Control Technology
• Four pumps can be switched on/off,
• Three float switches show three different filling levels,
• Three switches and two buttons can be switched by hand,
• Three LEDs (red, yellow, green) in the control panel can be controlled.
With the help of the switches and buttons, tasks such as emergency stop, process start and stop, and interruption can be implemented. The lamps enable malfunctions, errors and process states to be identified.
Scope of Delivery
Frame with control panel, two containers made of acrylic glass, pressure transmitter (fill level), adjustable pump, two centrifugal pumps, three level float switches, drain hose, power cable, instructions
Optional Extensions for the LC2030
Controllable valve, flow sensors (inlet and outlet), heating element, temperature sensor, circulation pump, cooler, pressure sensor, LC2030 training (software)
All signals (0/2…10V DC or 24V DC) are available via 4 mm laboratory sockets on the system control panel. The filling level is recorded via a float switch or a pressure sensor. The filling level is changed by controlling the three pumps and/or the valves. Switches and buttons on the control panel can be used flexibly for operation. Signal lights enable errors and process states to be displayed.
Technical Data
• Dimensions (W x D x H): 520 x 450 x 720 mm
• Container contents: 2 x ca. 8 l
• Weight: approx. 26 kg
Control Loops
• Level control with controllable pump,
• Level control with controllable valve (optional),
• Flow control with controllable pump (optional),
• Flow control with controllable valve (optional),
• Pressure control with controllable pump (optional),
• Temperature control with heating element and cooler (optional).
Open-Loop Control Technology
• Four pumps can be switched on/off,
• Three float switches show three different filling levels,
• Three switches and two buttons can be switched by hand,
• Three LEDs (red, yellow, green) in the control panel can be controlled.
With the help of the switches and buttons, tasks such as emergency stop, process start and stop, and interruption can be implemented. The lamps enable malfunctions, errors and process states to be identified.
Scope of Delivery
Frame with control panel, two containers made of acrylic glass, pressure transmitter (fill level), adjustable pump, two centrifugal pumps, three level float switches, drain hose, power cable, instructions
Optional Extensions for the LC2030
Controllable valve, flow sensors (inlet and outlet), heating element, temperature sensor, circulation pump, cooler, pressure sensor, LC2030 training (software)
Hall 6.1 | A002